Skip to content
  1. Feb 11, 2020
  2. Nov 21, 2019
    • jdeglavina's avatar
      small adjustments · 556abaa9
      jdeglavina authored
      - added SagPeakDetCfg, Sag and Voltage peak detect period and set to 20ms
      - adjusted power startup valuesto be more consistent
      - removed calibrationError since there is no checksum on the 32 (there is on the 36)
      - register numbers in comments
      556abaa9
  3. Nov 12, 2019
  4. Oct 26, 2019
  5. Jul 16, 2019
  6. Jun 28, 2019
  7. Jun 19, 2019
  8. Jun 18, 2019
  9. Jun 17, 2019
    • jdeglavina's avatar
      offsets & phase angle calibration · 6b921efe
      jdeglavina authored
      - Removed calculation that would not allow some metering values to ever be negative
      - Added function to calculate Power Offset values
      - Tuned offset register values which will make metering values more accurate
      - Calibrated phase angle for more accurate small current values
      6b921efe
  10. Jun 03, 2019
  11. May 25, 2019
  12. May 23, 2019
  13. May 14, 2019
    • jdeglavina's avatar
    • jdeglavina's avatar
      Updated the ATM90E32 library significantly · c128bb63
      jdeglavina authored
      - Replaced lineGain with much more useful PGAGain, which increases the gain on current channels. Useful if using smaller CTs (1x) or larger CTs, like 200A (4x). The default is 2x
      - Added config variable for line frequency. This allows the frequency setting to be switched in the front end software. Default is 60hz.
      - Fixed GetActivePower, GetApparentPower, GetPowerFactor - all of these were not taking into account the lower 16 bit register, and were not outputting the correct numbers
      - Fixed GetPowerFactor - the registers for power factor sometimes goes out of bounds for unknown reasons. Corrected this by doing a check on the output, and outputting 0 instead. Normally the value should be between -1 and 1.
      - Fixed GetPhaseAngle - should have been unsigned short instead of signed. The output now outputs between 0 and 360
      - Added classes for GetImportReactiveEnergy GetImportApparentEnergy, GetExportReactiveEnergy
      - Added check for frequency lo and hi thresholds based on lineFreq
      - Added check for voltage sag based on lineFreq, and adjustment based on lineFreq and ugain
      c128bb63
  14. May 07, 2019
  15. May 06, 2019
  16. Apr 30, 2019
  17. Mar 03, 2019
  18. Feb 19, 2019
  19. Nov 09, 2018
  20. Oct 19, 2018
  21. Oct 12, 2018
  22. Oct 08, 2018
  23. Sep 29, 2018
  24. Aug 26, 2018
Loading